Ethan Shipulski
Profile Information
- Name
- Mr. Ethan Shipulski
- Institution
- Oak Ridge National Laboratory
- Position
- Nuclear Mechanical Engineer
Publications:
|
"Postirradiation Examination of WIRE-21 Experiment Irradiated in the High Flux Isotope Reactor"
Ethan Shipulski, Peter Doyle, Christian Petrie, Wesley Jones, Bekah Petrosky, Denise Adorno Lopes, Jorge Carvajal, Shawn Stafford, Jeffrey Arndt,
Vol.
2026
Link
Westinghouse Electric Company is developing wireless sensors to monitor the centerline temperature and
internal pressure of commercial light-water reactor fuel rods during irradiation. Oak Ridge National
Laboratory and Westinghouse Electric Company developed the Wireless Instrumented RB Experiment
2021 (WIRE-21) to test wireless temperature and pressure sensor technologies in a removable beryllium
position in the High Flux Isotope Reactor. The experiment was irradiated for a total of 75 days, at
temperatures ranging from approximately 150°C to 400°C, resulting in a peak fast (energy > 0.1 MeV)
neutron fluence of about 3 × 1021 n/cm2. The temperature was intentionally cycled multiple times to
compare the response of the wireless temperature sensor to collocated thermocouples. Similarly, the
pressure sensor was actuated in multiple steps to compare the response of the wireless measurement to excore
pressure transducers (Petrie et al., 2023). After irradiation, the experiment was disassembled in the
Irradiated Fuels Examination Laboratory (IFEL) hot cell at Oak Ridge National Laboratory with the intent
to recover sensor and dosimetry components, document the as-irradiated condition of the hardware, and
investigate possible causes of the sensor behavior observed during irradiation.
The postirradiation examination successfully recovered and preserved key WIRE-21 components. After
the housing was removed using a milling machine, the internal experiment sections were examined. All
eight fiber-optic sensors were recovered, cut, and stored. The silicon carbide thermometry, temperature
sensor, pressure sensor, lower spacer, and selected pressure and temperature cable sections were also
removed and stored.
The metal bellows of the pressure sensor was found to be plastically deformed, indicating that it had been
properly pressurized during irradiation and generally behaved as expected. X-ray diffraction analysis of a
section of one of the irradiated inductor cores within the pressure sensor was performed and confirmed
the presence of phase-pure alpha ferrite (i.e., no unexpected phase transformations). Inductance testing
was performed on the irradiated pressure sensor cores using an unirradiated test coil, and DC resistance
measurements of the transceiver coils were also performed. The measurements with irradiated inductor
cores assembled inside unirradiated coils showed slightly reduced inductance compared to measurements
made with unirradiated cores, but the difference was not sufficient to explain the more significant
reductions in inductance that were observed in-pile. Therefore, it is suspected that degradation of the
inductor coils (specifically the wire wrapping) is responsible for the reduced inductance observed in-pile. |
Accomplishments