0034-1996-APT
LANSCE APT Irradiation 1996/1997/1999
- Program
- NSUF
- Project
- LANSCE APT Irradiation 1996/1997/1999
- Reactor
- LANSCE
- Reactor Position
- 17A
- Sample Id Code
- 0034-1996-APT
- Capsule
- 1
- Packet
- 6-9
- Material Code
- Inconel 718 (Inc718)
- Material Name
- Alloy 718
- Material Description
- Nickel Super Alloy-Precipitation Hardening
- Material Tags
-
Metal, Alloy, Inconel 718, UNS N07718, Structural
- KGT Num
- T15-18
- Specimen Type
- S-1 Tensile
- Dimensions (mm)
- 4.0 x 16.0 x 0.25 thick with 1.19 gauge width
- Number Of Samples
- 1
- Samples Remaining
- No Samples Remaining Defined
- Date Added
- No Date Added Defined
- Available for Research
-
Yes
- Anticipated Availability
- January 1, 2002
- Storage Facility
- Chemistry and Metallurgical Research Facility (Wing 9)
- Notes
- No Notes Defined
- Planned Temp (°C)
- 90.00
- Planned Dose (DPA)
- No planned Dose Value Defined
- Planned Fluence (n/cm²)
- No planned Fluence Value Defined
- Planned Flux (n/cm²/s)
- No planned Flux Value Defined
- Planned Environment
- Vacuum
- As Run Temp (°C)
- No As Run Temp Defined
- As Run Dose (DPA)
- 2.39
- As Run Total Dose (DPA)
- 2.39
- As Run Fluence (n/cm²)
- No as Run Fluence Value Defined
- As Run Total Fluence (n/cm²)
- 0
- As Run Flux (n/cm²/s)
- No as Run Flux Value Defined
- As Run Environment
- No As Run Environment Defined
- Composition by Wt. (%)
-
Ni
-22.434Fe
-17Cr
-4.75Nb
-2.8Mo
-1Co
-0.65Ti
-0.35Mn
-0.35Si
-0.3Cu
-0.2Al
-0.08C
-0.05Ta
-0.015P
-0.015S
-0.006B