2129-1996-APT
LANSCE APT Irradiation 1996/1997/1999
- Program
- NSUF
- Project
- LANSCE APT Irradiation 1996/1997/1999
- Reactor
- LANSCE
- Reactor Position
- 18C
- Sample Id Code
- 2129-1996-APT
- Capsule
- 24
- Packet
- 2-27
- Material Code
- 9Cr-1Mo (6113)
- Material Name
- Fe-Cr-Mo Systems
- Material Description
- Ferritic Martensitic Steel-Normalized and Tempered
- Material Tags
-
Metal, Steel, Alloy, Ferrous, Ferritic/Martensitic (F/M), Fast fission, Structural, 9Cr-1Mo
- KGT Num
- B43
- Specimen Type
- TEM
- Dimensions (mm)
- 0.25 thick
- Number Of Samples
- 1
- Samples Remaining
- No Samples Remaining Defined
- Date Added
- No Date Added Defined
- Available for Research
-
Yes
- Anticipated Availability
- January 1, 2002
- Storage Facility
- Chemistry and Metallurgical Research Facility (Wing 9)
- Notes
- No Notes Defined
- Planned Temp (°C)
- 90.00
- Planned Dose (DPA)
- No planned Dose Value Defined
- Planned Fluence (n/cm²)
- No planned Fluence Value Defined
- Planned Flux (n/cm²/s)
- No planned Flux Value Defined
- Planned Environment
- Vacuum
- As Run Temp (°C)
- No As Run Temp Defined
- As Run Dose (DPA)
- 2.39
- As Run Total Dose (DPA)
- 2.39
- As Run Fluence (n/cm²)
- No as Run Fluence Value Defined
- As Run Total Fluence (n/cm²)
- 0
- As Run Flux (n/cm²/s)
- No as Run Flux Value Defined
- As Run Environment
- No As Run Environment Defined
- Composition by Wt. (%)
-
Fe
-9Cr
-1Mo
-0.3Mn
-0.25Si
-0.15C
-0.025P
-0.025S