"Micro-Pocket Fission Detectors (MPFDs) for In-Core Neutron Detection"
Douglas McGregor, Michael Reichenberger, Jeremy Roberts, Troy Unruh, Philip Ugorowski, Takashi Ito, Sarah Stevenson, Daniel Nichols,
Annals of Nuclear Energy
Vol. 87
2015
318-323
Link
Neutron sensors capable of real-time measurement of neutrons in high-flux environments are necessary for tests aimed at demonstrating the performance of experimental nuclear reactor fuels and materials in material test reactors (MTRs). In-core Micro-Pocket Fission Detectors (MPFDs) have been studied at Kansas State University for many years. Previous MPFD prototypes were successfully built and tested with promising results. Efforts are now underway to develop advanced MPFDs with radiation-resistant, high-temperature materials capable of withstanding irradiation test conditions in high performance material and test reactors. Stackable MPFDs have been designed, built, and successfully demonstrated as in-core neutron sensors. Advances in the electrodeposition and measurement of neutron reactive material, along with refinements to composition optimization simulations, have enhanced the capabilities of contemporary MPFDs. |
The Nuclear Science User Facilities (NSUF) is the U.S. Department of Energy Office of Nuclear Energy's only designated nuclear energy user facility. Through peer-reviewed proposal processes, the NSUF provides researchers access to neutron, ion, and gamma irradiations, post-irradiation examination and beamline capabilities at Idaho National Laboratory and a diverse mix of university, national laboratory and industry partner institutions.