Advanced Test Reactor (ATR)

Idaho National Laboratory Idaho


Institution Name
Idaho National Laboratory
Name
Advanced Test Reactor (ATR)
Building
TRA-670
Primary Facility Type
Reactor
Secondary Facility Type
Gamma Irradiations
Tertiary Facility Type
No Tertiary Facility Type Defined
Reactor Type
Test
Thermal Power (MW)
250
Pulse Power
0
Thermal Flux (n/cm^2/s)
1E+15
Fast Flux (n/cm^2/s)
5E+14
In Core Locations
66
Ex Core Locations
34
PTS
1
Flow Loops
6
Beam Ports
0
Operating Cycle
~55-60 day standard cycles / ~5-14 day high power cycles
Core Functions
Advanced Fuels and materials irradiation. Water-cooled, high-flux test reactor.
Unique Functions
Six in-pile pressurized water loops currently provide prototypic PWR conditions (pressure, temperature, flow, water chemistry) for fuel and material samples with the ability to tailor the neutron flux to meet desired conditions. Each loop has a full range of instrumentation capabilities. Two of the six loops have transient testing capabilities. The ATR has a capacity for up to nine water loops.
Hotwork Facilities
HFEF
Support Equipment
MFC, Test Train Assembly Facility
Radiological Limit
>1R/hr @ 30cm
Materials Allowed
alpha/beta/gamma
Sample Encapsulation
none
Atmosphere
gas/PWR
Commissioning Date
1967
Recent Upgrade
2023
RAM License
Department of Energy
License End Date
2099
Docket Number
0
User Facility
Yes
User Org Web Page
nsuf.inl.gov
Proposal Web Page
nsuf.inl.gov
GAIN Partner
No
NSUF Partner
Yes
NE Use Percentage
50
Utilization Hours
No Utilization Hours Defined
Number Of Users
No Number Of Users Defined
Number Of Staff
305
Scheduling Web Page
No Scheduling Web Page Defined
Point Of Contact
Keith Jewell
Point Of Contact Email
[email protected]
Point Of Contact Addr1
No Point Of Contact Addr1 Defined
Point Of Contact Addr2
No Point Of Contact Addr2 Defined
Point Of Contact City
No Point Of Contact City Defined
Point of Contact State
Idaho
Point Of Contact Zip
No Point Of Contact Zip Defined
Point Of Contact Phone
(208) 526-3944
Website URL
https://inl.gov/advanced-test-reactor/
Date Of Data
October 17, 2023